The Indicators accept all industrial standard input signals, like 4 to 20 mA DC, AC/DC Voltage, AC/DC Current, Resistance, Strain-gauge, Frequency and all temperature sensors like RTD Pt-100, Thermocouples, etc. The process value is displayed on a 4 digit seven-segment LED digital display. Up to four relay outputs are available as control options, each of which can switch a load of up to 10 Ampere rating.
The Digital Indicating Controllers are available in several dimensions in panel mounted execution and operate on AC or DC power supply, as required. Options include analog retransmission signals, Blind control option, DIN rail mount / weather-proof / flame-proof executions, Remote Control operation, etc.
All ASHE instruments carry a lifetime warranty against defects in components and workmanship.
The various models available in this product category are :
Model | Type | Input | Outputs | No. Of Outputs | Power Supply | Mounting | Load Ratings | Switching Time | Dimensions | Execution | Relay Outputs | Control Outputs | Analog Outputs | Comm Outputs | No of Fans | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CY-40 | Digital Indicator | 4-20 mADC, 0-10 VDC, RTD Pt-100, Thermocouple, etc. |
90 to 270 VAC, 50/60 Hz |
72x72x55 mm |
Panel mount | 0 | - | Nill | ||||||||
CY-50 | Digital Indicator | 4-20 mADC, 0-10 VDC, RTD Pt-100, Thermocouple, etc. | 90 to 270 VAC, 50/60 Hz |
48x48x90 mm |
Panel mount | 0 | - | Nill | ||||||||
CY-60 | Digital Indicator | 4-20 mADC, 0-10 VDC, RTD Pt-100, Thermocouple, etc. |
90 to 270 VAC, 50/60 Hz |
48x96x55 mm |
Panel mount | 0 | 4 to 20 mA DC (Optional) | RS485 on Modbus RTU | ||||||||
CY-70 | Digital Indicator | 4-20 mADC, 0-10 VDC, RTD Pt-100, Thermocouple, etc. |
90 to 270 VAC, 50/60 Hz |
96x96x55 mm |
Panel mount | 0 | 4 to 20 mA DC (Optional) | Nill | ||||||||
CY-41 | Digital Indicator with single relay control | 4-20 mADC, 0-10 VDC, RTD Pt-100, Thermocouple, etc. |
90 to 270 VAC, 50/60 Hz |
72x72x55 mm |
Panel mount | 1 | 4 to 20 mA DC (Optional) | Nill | ||||||||
CY-51 | Digital Indicator with single relay control | 4-20 mADC, 0-10 VDC, RTD Pt-100, Thermocouple, etc. |
90 to 270 VAC, 50/60 Hz |
48x48x90 mm |
Panel mount | 1 | 4 to 20 mA DC (Optional) | Nill | ||||||||
CY-61 | Digital Indicator with single relay control | 4-20 mADC, 0-10 VDC, RTD Pt-100, Thermocouple, etc. |
90 to 270 VAC, 50/60 Hz |
48x96x55 mm |
Panel mount | 1 | 4 to 20 mA DC (Optional) | RS485 on Modbus RTU | ||||||||
CY-71 | Digital Indicator with single relay control | 4-20 mADC, 0-10 VDC, RTD Pt-100, Thermocouple, etc |
90 to 280 VAC, 50/60 Hz |
96x96x55 mm |
Panel mount | 1 | 4 to 20 mA DC (Optional) | Nill | ||||||||
CY-42 | Digital Indicator with two relay control | 4-20 mADC, 0-10 VDC, RTD Pt-100, Thermocouple, etc. |
90 to 290 VAC, 50/60 Hz |
72x72x55 mm | Panel mount | 2 | 4 to 20 mA DC (Optional) | Nill | ||||||||
CY-52 | Digital Indicator with two relay control | 4-20 mADC, 0-10 VDC, RTD Pt-100, Thermocouple, etc. |
90 to 2100 VAC, 50/60 Hz |
48x48x90 mm | Panel mount | 2 | 4 to 20 mA DC (Optional) | Nill | ||||||||
CY-62 | Digital Indicator with two relay control | 4-20 mADC, 0-10 VDC, RTD Pt-100, Thermocouple, etc. |
90 to 2110 VAC, 50/60 Hz |
48x96x55 mm | Panel mount | 2 | 4 to 20 mA DC (Optional) | RS485 on Modbus RTU | ||||||||
CY-72 | Digital Indicator with two relay control | 4-20 mADC, 0-10 VDC, RTD Pt-100, Thermocouple, etc. |
90 to 2120 VAC, 50/60 Hz |
96x96x55 mm |
Panel mount | 2 | 4 to 20 mA DC (Optional) | Nill |