The instruments are designed for use in industries where high degree of vibration, inclement weather and corrosive atmospheres prevail.
The electronics is mounted inside low-copper, epoxy coated die-cast Aluminum enclosures, which have a Safety Glass window for process and control indication. For more aggressive environments, Stainless Steel SS-316 versions are also offered. Instruments such as Digital Loop Powered Indicators, Digital process Indicators for all applications, On/Off Controllers, Flow Totalizers and Batch Controllers, Temperature Transmitters, Earthing Relays, etc., are offered in this execution.
The enclosures are compact, rugged and aesthetically designed. They are offered in attractive colors for Aluminum enclosures and Natural Silver color for Stainless Steel SS-316 enclosures. Complete mounting accessories are offered for field or 2” pipe mounting. The enclosures are certified for use in Gas Groups IIA and IIB and Zone 1 and 2 atmosphere by CIMFR, Dhanbad for Flame-proof applications as per IS:2148-1981 and Weather-proof applications for IP-65 protection as per IS:13947(Part-1):1993.
All ASHE instruments carry a lifetime warranty against defects in components and workmanship.
The various models available in this product category are :
Model | Type | Input | Outputs | No. Of Outputs | Power Supply | Mounting | Load Ratings | Switching Time | Dimensions | Execution | Relay Outputs | Control Outputs | Analog Outputs | Comm Outputs | No of Fans | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
JX-40 | Digital Indicator in FLP execution | 4-20 mA DC, RTD Pt-100, etc. |
90 to 270 VAC, 50/60Hz / 24 VDC |
Hazardous Area (Exproof) | 140x130x130 mm |
140x130x130 mm | Field mount Exd (Haz Area) | 0 | 4 to 20 mA DC (Optional) | Nill | ||||||
JX-42 | Digital Indicator with two Relay control in FLP | 4-20 mA DC, RTD Pt-100, etc. |
90 to 270 VAC, 50/60Hz / 24 VDC |
Hazardous Area (Exproof | 140x130x130 mm |
140x130x130 mm | Field mount Exd (Haz Area) | 2 | 4 to 20 mA DC (Optional) | Nill | ||||||
JX-47 | Digital Indicator with two Relay control in FLP | 4 to 20 mA DC | 90 to 270 VAC, 50/60Hz / 24 VDC |
140x130x130 mm | Field mount Exd (Haz Area) | 2 | 4 to 20 mA DC (Optional) | RS485 on Modbus RTU | ||||||||
JX-60 | Digital Indicator with two Relay control in FLP | RS485 on Modbus RTU | 90 to 270 VAC, 50/60Hz / 24 VDC |
140x130x130 mm | Field mount Exd (Haz Area) | 0 | 4 to 20 mA DC (Optional) | Nill | ||||||||
JX-62 | Digital Indicator with two Relay control in FLP | 4 to 20 mA DC | 90 to 270 VAC, 50/60Hz / 24 VDC |
140x130x130 mm | Field mount Exd (Haz Area) | 2 | 4 to 20 mA DC (Optional) | RS485 on Modbus RTU | ||||||||
JX-67 | Digital Indicator with two Relay control in FLP | RS485 on Modbus RTU | 90 to 270 VAC, 50/60Hz / 24 VDC |
140x130x130 mm | Field mount Exd (Haz Area) | 2 | 4 to 20 mA DC (Optional) | Nill |