The Indicators accept all industrial standard input signals, like 4 to 20 mA DC, AC/DC Voltage, AC/DC Current, Resistance, Strain-gauge, Frequency and all temperature sensors like RTD Pt-100, Thermocouples, etc. The process value is displayed on a 4 digit seven-segment LED digital display. Up to four relay outputs are available as control options, each of which can switch a load of up to 10 Ampere rating.

The Digital Indicating Controllers are available in several dimensions in panel mounted execution and operate on AC or DC power supply, as required. Options include analog retransmission signals, Blind control option, DIN rail mount / weather-proof / flame-proof executions, Remote Control operation, etc.

All ASHE instruments carry a lifetime warranty against defects in components and workmanship.

The various models available in this product category are :


Model Type Input Outputs No. Of Outputs Power Supply Mounting Load Ratings Switching Time Dimensions Execution Relay Outputs Control Outputs Analog Outputs Comm Outputs No of Fans PDF
AK-60 Digital Indicator 4-20 mADC,
0-10 VDC,
RTD Pt-100,
Thermocouple, etc.
90 to 270 VAC,
50/60
Hz
48x96x55 mm Panel mount 0 4 to 20 mA DC (Optional) RS485 on Modbus RTU
AK-61 Digital Indicator with one Relay control 4-20 mADC,
0-10 VDC,
RTD Pt-100,
Thermocouple, etc.
90 to 270
VAC,
50/60 Hz
48x96x55 mm Panel mount 1 4 to 20 mA DC (Optional) RS485 on Modbus RTU
AK-62 Digital Indicator with two Relay control 4-20 mADC,
0-10 VDC,
RTD Pt-100,
Thermocouple, etc.
90 to 270 VAC, 50/60 Hz 48x96x55
mm
Panel mount 2 4 to 20 mA DC (Optional) RS485 on Modbus RTU
AF-70 Digital Indicator 4-20 mADC,
0-10 VDC,
RTD Pt-100,
Thermocouple, etc.
90 to 270
VAC,
50/60 Hz
96x96x75
mm
96x96x55
mm
Panel mount 0 4 to 20 mA DC (Optional) Nill
AF-71 Digital Indicator with one Relay control 4-20 mADC,
0-10 VDC,
RTD Pt-100,
Thermocouple, etc.
90 to 270 VAC,
50/60 Hz
96x96x55
mm
Panel mount 1 4 to 20 mA DC (Optional) Nill
AF-72 Digital Indicator with two Relay control 4-20 mADC,
0-10 VDC,
RTD Pt-100,
Thermocouple, etc.
90 to 270 VAC,
50/60 Hz
96x96x75
mm
96x96x55
mm
Panel mount 2 4 to 20 mA DC (Optional) Nill
AF-73 Digital Indicator with three relay control 4-20 mADC, 0-10 VDC, RTD Pt-100, Thermocouple, etc. 90 to 270
VAC,
50/60 Hz
96x96x55 mm Panel mount 3 4 to 20 mA DC (Optional) Nill
AF-74 Digital Indicator with four relay control 4-20 mADC
, 0-10 VDC,
RTD Pt-100,
Thermocouple, etc.
90 to 270
VAC,
50/60 Hz
96x96x55 mm Panel mount 4 4 to 20 mA DC (Optional) Nill